Expert Details

Medical Device Accidents, Surgical Fires, Oxygen Safety, Medical Gas Piping, Failure Analysis

ID: 729827 Pennsylvania, USA

Request Expert

Eng. Expert has been conducting medical device accident investigations for 25 years and product failure analysis for more than 30 years. These failures sometimes involve the actual failure of a metal, plastic, or glass part or a failure of the user. He has had graduate and continuing educational training in failure analysis, stress analysis, fractography, material properties, and electron microscopy. He has brought these skills to play in more than 250 investigations, which resulted in 12 depositions and 3 trial testimonies. The vast majority of his investigations settled out of court because of his properly identifiying the cause of the accident or problem. He is also an expert in oxygen safety and surgical fire safety, having written extensively on both topics.

Several of Eng. Expert's investigations involved surgical staplers, which are used instead of sutures to speed and reduce the complexity of certain surgeries. By examination of the staplers, recovered staples, and excised tissue, he was able to demonstrate that the stapler that these were cases of device misuse and not the fault of the device.By examination of the location of the air intake for a medical air system, Eng. Expert showed that intermittant contaminants were entrained with the intake air and led to poisoning deaths of neonates.A surgical fire case involved an emergency procedure in which an alcohol-based skin prep was inappropriately used. Eng. Expert demonstrated how the fire was started and spread causing the pattern of burns to the patient.Several of Eng. Expert's cases involved catheters. In one case, simple observation of the failure surface of the catheter showed that it was cut with scissors. It was possible that this was a user error or a purposeful act.A purported case of frostbite was attributed to a cooling pad that used ice water. Eng. demonstrated that the device could not cause frostbite and that the injuries sustained were most likely caused by long exposure to wet and cold contrary to the device's and doctor's instuctions for use.

Education

Year Degree Subject Institution
Year: 1986 Degree: ABD PhD Subject: Applied Mechanics Institution: Drexel University
Year: 1974 Degree: MS Subject: Engineering Science and Mechanics Institution: VA Tech
Year: 1972 Degree: BS Subject: Engineering Mechanics Institution: Penn State

Work History

Years Employer Title Department
Years: 2010 to Present Employer: Undisclosed Title: Senior Engineering Consultant Department:
Responsibilities:
Eng. Expert provides healthcare and engineering consultation, research, investigation, writing, and testimony.
Years Employer Title Department
Years: 1987 to 2010 Employer: ECRI Institute Title: Associate Director Department:
Responsibilities:
Eng. Expert has investigated more than 250 medical device accidents and fires for healthcare organizations, insurers, and law firms. he was deposed 10 times and testified at trial twice. He assisted standards writing committees in U.S. and Canada. He assisted in management of group of about 20 engineers and scientists in engineering projects and journal publication. Also wrote articles for a peer-reviewed journal. Finally he planned, executed, and wrote evaluations of medical devices.

Additional Experience

Expert Witness Experience
Eng. Expert has been deposed 12 times and hsa testified at trial three times. He has been in both Federal and state courts.

Career Accomplishments

Associations / Societies
American Society of Mechanical Engineers, Amerian Society for Materials, National Society of Professinla Engineers, National Academy of Forensic Engineers.
Licenses / Certifications
Professional Engineer registered in Pennsylvania
Publications and Patents Summary
Eng. Expert has published more than 150 peer-reviewed articles and has given more than 160 lectures, mostly on healthcare technology topics.

Fields of Expertise

Request Expert

Dev Tool:

Request: expert/medical-device-accidents-surgical-fires-oxygen-safety-medical-gas-piping-failure-analysis
Matched Rewrite Rule: expert/([^/]+)(?:/([0-9]+))?/?$
Matched Rewrite Query: experts=medical-device-accidents-surgical-fires-oxygen-safety-medical-gas-piping-failure-analysis&page=
Loaded Template: single-experts.php